A compact incoherent broadband cavity-enhanced absorption spectrometer for trace detection of nitrogen oxides, iodine oxide and glyoxal at levels below parts per billion for field applications

We present a compact, affordable and robust instrument based on incoherent broadband cavity-enhanced absorption spectroscopy (IBBCEAS) for simultaneous detection of NOx, IO, CHOCHO and O3 in the 400–475 nm wavelength region. The instrument relies on the injection of a high-power LED source in a high...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Atmospheric measurement techniques 2020-08, Vol.13 (8), p.4317-4331
Hauptverfasser: Barbero, Albane, Blouzon, Camille, Savarino, Joël, Caillon, Nicolas, Dommergue, Aurélien, Grilli, Roberto
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:We present a compact, affordable and robust instrument based on incoherent broadband cavity-enhanced absorption spectroscopy (IBBCEAS) for simultaneous detection of NOx, IO, CHOCHO and O3 in the 400–475 nm wavelength region. The instrument relies on the injection of a high-power LED source in a high-finesse cavity (F∼33 100), with the transmission signal being detected by a compact spectrometer based on a high-order diffraction grating and a charge-coupled device (CCD) camera. A minimum detectable absorption of 2.0×10-10 cm−1 was achieved within ∼22 min of total acquisition, corresponding to a figure of merit of 1.8×10-10 cm−1 Hz-1/2 per spectral element. Due to the multiplexing broadband feature of the setup, multi-species detection can be performed with simultaneous detection of NO2, IO, CHOCHO and O3 achieving detection limits of 11, 0.3, 10 ppt (parts per trillion) and 47 ppb (parts per billion) (1σ) within 22 min of measurement, respectively (half of the time is spent on the acquisition of the reference spectrum in the absence of the absorber, and the other half is spent on the absorption spectrum). The implementation on the inlet gas line of a compact ozone generator based on electrolysis of water allows for the measurement of NOx (NO+NO2) and therefore an indirect detection of NO with detection limits for NOx and NO of 10 and 21 ppt (1σ), respectively. The device has been designed to fit in a 19 in., 3U (5.25 in.) rack-mount case; weighs 15 kg; and has a total electrical power consumption of
ISSN:1867-8548
1867-1381
1867-8548
DOI:10.5194/amt-13-4317-2020