Analysis of a Pollution Transmission Process in Hefei City Based on Mobile Lidar

The air pollution has been regional in China with the development of economy. To monitoring the air pollution transmission, a new technique, mobile lidar system (GBQ-S01), was introduced. In this paper, a pollution transmission process happened on October 26 th , 2017, was analyzed with the use of m...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Hauptverfasser: Zhang, Shuai, Zhou, Zhaoming, Ye, Conglei, Shi, Jibing, Wang, Peng, Liu, Dong
Format: Tagungsbericht
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:The air pollution has been regional in China with the development of economy. To monitoring the air pollution transmission, a new technique, mobile lidar system (GBQ-S01), was introduced. In this paper, a pollution transmission process happened on October 26 th , 2017, was analyzed with the use of mobile lidar, air quality monitoring stations data, and Hysplit backward trajectories. The results showed that the polluted air mass was transferred from northeast under the force of air pressure. Under the influences of air pollution transmission and bad meteorological diffusion conditions, The PM 10 quality concentrations in Hefei increased a lot within 5 hours; among all the 10 national air quality monitoring stations, the Luyang District (the northernmost one) and Changjiang Middle Road (the easternmost one) received the most serious impact with PM 10 concentration reached up to 252 μg/m 3 and 219 μg/m 3 at 22:00 (Beijing Time).
ISSN:2100-014X
2101-6275
2100-014X
DOI:10.1051/epjconf/202023702006