Experimental determination of the cooling efficiency of a high-temperature surface by a pneumatic nozzle

The cooling of surfaces that perceive high heat fluxes (more than 7 MW/m 2 ) at the current pace of development of the energy sector will become one of the main problems of the near future. In this paper, as one of the options for effective cooling of high-temperature surfaces of various geometries,...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:E3S web of conferences 2023-01, Vol.459, p.5002
Hauptverfasser: Demidov, Andrey Sergeevich, Zakharenkov, Alexander Valentinovich, Komov, Alexander Timofeevich, Dedov, Alexey Victorovich
Format: Artikel
Sprache:eng
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:The cooling of surfaces that perceive high heat fluxes (more than 7 MW/m 2 ) at the current pace of development of the energy sector will become one of the main problems of the near future. In this paper, as one of the options for effective cooling of high-temperature surfaces of various geometries, the results of an experimental study of the cooling process by a spray flow directed perpendicular to the cooled surface are presented. Two different types of nozzles are used for cooling. Water consumption varied in the range (8.3÷25.0)∙10 −3 kg/s , air consumption in the range (0.3÷1.1)∙10 −3 kg/s . The maximum value of the density of the removed heat flux for one of the nozzles is 11.3 MW/m 2 at a water flow rate 25.0∙10 −3 kg/s , the average value of the heat transfer coefficient during spray cooling was about 100 kW/m 2 K.
ISSN:2267-1242
2267-1242
DOI:10.1051/e3sconf/202345905002