Flow-induced alignment of titanium dioxide nanorods in polyolefin tubes for use in catheters
[Display omitted] •Flow manipulation is a simple and feasible strategy for the mass-production of catheters with stiffness-variable segments.•Using a time-dependent helical flow, differently aligned TiO2 nanorods can be constructed along the axial direction of a single catheter.•Regulating the align...
Gespeichert in:
Veröffentlicht in: | Materials & design 2023-09, Vol.233, p.112277, Article 112277 |
---|---|
Hauptverfasser: | , , , , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
Zusammenfassung: | [Display omitted]
•Flow manipulation is a simple and feasible strategy for the mass-production of catheters with stiffness-variable segments.•Using a time-dependent helical flow, differently aligned TiO2 nanorods can be constructed along the axial direction of a single catheter.•Regulating the alignment of TiO2 nanorods can obtain stiffness-variable segments.•Catheters with multiple variable stiffness segments along the axial direction exhibited reduced interventional loads and elevated rotational synchronization.
Interventional catheters are the pivotal components of catheter-assisted intervention therapy. However, the inevitable contact and friction between catheters and complex human channels usually lead to severe patient burdens. A fabrication strategy for variable-stiffness catheters based on time-dependent helical flow was developed by regulating the alignment of titanium dioxide (TiO2) nanorods in polyolefin elastomer (POE) catheters. In particular, the uniaxial and off-axial alignments of the TiO2 nanorods were manipulated to adjust the mechanical properties of each section in the POE catheters, where the processing flow pattern was transformed from axial to helical. To achieve the desired performance in practical applications, two catheters with a programmable helix angle of embedded TiO2 nanorods along the axial direction were designed. Correspondingly, the as-designed catheters displayed remarkably reduced interventional loads (e.g., a maximum reduction of 49.3% and 39.7% in single- and multi-curvature channels, respectively) and an enhancement of 50% in rotation synchronization, indicating promising potential for application in catheter-assisted interventional therapy. This study proposes an effective structuring design strategy for composed catheters with variable-stiffness segments that can be extended to all interventional catheter production techniques. |
---|---|
ISSN: | 0264-1275 |
DOI: | 10.1016/j.matdes.2023.112277 |