Artificial intelligence based glaucoma and diabetic retinopathy detection using MATLAB - retrained AlexNet convolutional neural network [version 2; peer review: 2 approved with reservations]
Background Glaucoma and diabetic retinopathy (DR) are the leading causes of irreversible retinal damage leading to blindness. Early detection of these diseases through regular screening is especially important to prevent progression. Retinal fundus imaging serves as the principal method for diagnosi...
Gespeichert in:
Veröffentlicht in: | F1000 research 2023, Vol.12, p.14-14 |
---|---|
Hauptverfasser: | , , , , , , , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
Zusammenfassung: | Background
Glaucoma and diabetic retinopathy (DR) are the leading causes of irreversible retinal damage leading to blindness. Early detection of these diseases through regular screening is especially important to prevent progression. Retinal fundus imaging serves as the principal method for diagnosing glaucoma and DR. Consequently, automated detection of eye diseases represents a significant application of retinal image analysis. Compared with classical diagnostic techniques, image classification by convolutional neural networks (CNN) exhibits potential for effective eye disease detection.
Methods
This paper proposes the use of MATLAB - retrained AlexNet CNN for computerized eye diseases identification, particularly glaucoma and diabetic retinopathy, by employing retinal fundus images. The acquisition of the database was carried out through free access databases and access upon request. A transfer learning technique was employed to retrain the AlexNet CNN for non-disease (Non_D), glaucoma (Sus_G) and diabetic retinopathy (Sus_R) classification. Moreover, model benchmarking was conducted using ResNet50 and GoogLeNet architectures. A Grad-CAM analysis is also incorporated for each eye condition examined.
Results
Metrics for validation accuracy, false positives, false negatives, precision, and recall were reported. Validation accuracies for the NetTransfer (I-V) and netAlexNet ranged from 89.7% to 94.3%, demonstrating varied effectiveness in identifying Non_D, Sus_G, and Sus_R categories, with netAlexNet achieving a 93.2% accuracy in the benchmarking of models against netResNet50 at 93.8% and netGoogLeNet at 90.4%.
Conclusions
This study demonstrates the efficacy of using a MATLAB-retrained AlexNet CNN for detecting glaucoma and diabetic retinopathy. It emphasizes the need for automated early detection tools, proposing CNNs as accessible solutions without replacing existing technologies. |
---|---|
ISSN: | 2046-1402 2046-1402 |
DOI: | 10.12688/f1000research.122288.2 |