Evaluation of a loop-mediated isothermal amplification method for the detection of Listeria monocytogenes in dairy food
Objective of the present study was to test the performances of a loop-mediated isothermal amplification (LAMP)-based method for the detection of , with particular focus on the dairy products. The specificity of the method was evaluated on 42 different spp. strains from collections, food and environm...
Gespeichert in:
Veröffentlicht in: | Italian journal of food safety 2017-12, Vol.6 (4), p.6890 |
---|---|
Hauptverfasser: | , , , , , , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
Zusammenfassung: | Objective of the present study was to test the performances of a loop-mediated isothermal amplification (LAMP)-based method for the detection of
, with particular focus on the dairy products. The specificity of the method was evaluated on 42 different
spp. strains from collections, food and environmental samples. 100% (32 of 32) of the
strains were correctly recognised, and none of other 10
spp. strains was misidentified. The sensitivity was evaluated on four
strains from different sources. The instrument was able to detect 10-400 CFU/mL. The ability to detect low initial numbers of
(0.3-0.7 Log CFU/g) was also evaluated, in duplicate, in pasteurised milk (whole and skimmed) and dairy samples (fresh ricotta, crescenza, mascarpone, mozzarella, cottage cheese, cream cheese, taleggio, gorgonzola). The analysis was performed after 18, 24 and 48 h of incubation, and was coupled with the count of
in the broth. Microbial loads were insufficient to achieve a positive result after 18 and 24 h in most of the samples; after 48 h, all the products, except taleggio and one gorgonzola sample, were identified as positive; the sensitivity of the method when applied to contaminated dairy foods was about 5 Log CFU/g. The LAMP method tested can be considered a very useful tool, as it is a costeffective and easy-functioning method. The preliminary data obtained should be confirmed with a validation process taking into account different food typologies. |
---|---|