Assessment of the accuracy of malaria microscopy in private health facilities in Entebbe Municipality, Uganda: a cross-sectional study

Although microscopy remains the gold standard for malaria diagnosis, little is known about its accuracy in the private health facilities in Uganda. This study evaluated the accuracy of malaria microscopy, and factors associated with inaccurate smear results at private health facilities in Entebbe Mu...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Malaria journal 2021-06, Vol.20 (1), p.250-9, Article 250
Hauptverfasser: Mutabazi, Tobius, Arinaitwe, Emmanuel, Ndyabakira, Alex, Sendaula, Emmanuel, Kakeeto, Alex, Okimat, Paul, Orishaba, Philip, Katongole, Simon Peter, Mpimbaza, Arthur, Byakika-Kibwika, Pauline, Karamagi, Charles, Kalyango, Joan Nakayaga, Kamya, Moses R, Dorsey, Grant, Nankabirwa, Joaniter I
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:Although microscopy remains the gold standard for malaria diagnosis, little is known about its accuracy in the private health facilities in Uganda. This study evaluated the accuracy of malaria microscopy, and factors associated with inaccurate smear results at private health facilities in Entebbe Municipality, Uganda. Between April and May 2018, all patients referred for a malaria smear in 16 private health facilities in Entebbe municipality were screened, and 321 patients were enrolled. A questionnaire was administered to collect demographic and clinical information, facility-based smear results were recorded from the participant's consultation notes, and a research slide was obtained for expert microscopy during exit interview. A health facility assessment was conducted, and information on experience in performing malaria microscopy was collected from all facility personnel reading smears and the data was linked to the participant's clinic visit. The test positivity rate of malaria parasitaemia was 15.0% by expert microscopy. The sensitivity, specificity and negative predictive value of the facility-based microscopy were high (95.8%, 90.1 and 99.2%, respectively). However; the positive predictive value (PPV) was low with 27/73 (63%) patients diagnosed with malaria not having the disease. Majority of the inaccurate results were from 2 of the 23 laboratory personnel reading the smears. The factors associated with inaccurate smear readings included being read by a technician; (1) who had less than 5 years' experience in reading malaria smears (adjusted Odds Ratio [aOR] = 9.74, 95% confidence interval [CI] (1.06-89.5), p-value = 0.04), and (2) who was examining less than 5 smears a day (aOR = 38.8, 95% CI 9.65-156, p-value 
ISSN:1475-2875
1475-2875
DOI:10.1186/s12936-021-03787-y