Cerebral cortex dose sparing for glioblastoma patients: IMRT versus robust treatment planning
To date, patients with glioblastoma still have a bad median overall survival rate despite radiation dose-escalation and combined modality treatment. Neurocognitive decline is a crucial adverse event which may be linked to high doses to the cortex. In a planning study, we investigated the impact of d...
Gespeichert in:
Veröffentlicht in: | Radiation oncology (London, England) England), 2018-02, Vol.13 (1), p.20-20, Article 20 |
---|---|
Hauptverfasser: | , , , , , , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
Zusammenfassung: | To date, patients with glioblastoma still have a bad median overall survival rate despite radiation dose-escalation and combined modality treatment. Neurocognitive decline is a crucial adverse event which may be linked to high doses to the cortex. In a planning study, we investigated the impact of dose constraints to the cerebral cortex and its relation to the organs at risk for glioblastoma patients.
Cortical sparing was implemented into the optimization process for two planning approaches: classical intensity-modulated radiotherapy (IMRT) and robust treatment planning. The plans with and without objectives for cortex sparing where compared based on dose-volume histograms (DVH) data of the main organs at risk. Additionally the cortex volume above a critical threshold of 28.6 Gy was elaborated. Furthermore, IMRT plans were compared with robust treatment plans regarding potential cortex sparing.
Cortical dose constraints result in a statistically significant reduced cerebral cortex volume above 28.6 Gy without negative effects to the surrounding organs at risk independently of the optimization technique. For IMRT we found a mean volume reduction of doses beyond the threshold of 19%, and 16% for robust treatment planning, respectively. Robust plans delivered sharper dose gradients around the target volume in an order of 3 - 6%. Aside from that the integration of cortical sparing into the optimization process has the potential to reduce the dose around the target volume (4 - 8%).
We were able to show that dose to the cerebral cortex can be significantly reduced both with robust treatment planning and IMRT while maintaining clinically adequate target coverage and without corrupting any organ at risk. Robust treatment plans delivered more conformal plans compared to IMRT and were superior in regards to cortical sparing. |
---|---|
ISSN: | 1748-717X 1748-717X |
DOI: | 10.1186/s13014-018-0953-x |