Clinical Outcomes of Enhanced Monofocal (Mono-EDOF) Intraocular Lenses with the Mini-Monovision Technique versus Trifocal Intraocular Lenses: A Comparative Study
It was aimed to compare the clinical results of the mini-monovision technique (MMV) with enhanced monofocal intraocular lens (IOL) and trifocal IOL applications and to evaluate the intereye differences in the MMV group. This retrospective observational study evaluated the results of cataract surgeri...
Gespeichert in:
Veröffentlicht in: | Turk oftalmoloji gazetesi 2024-08, Vol.54 (4), p.190-197 |
---|---|
Hauptverfasser: | , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
Zusammenfassung: | It was aimed to compare the clinical results of the mini-monovision technique (MMV) with enhanced monofocal intraocular lens (IOL) and trifocal IOL applications and to evaluate the intereye differences in the MMV group.
This retrospective observational study evaluated the results of cataract surgeries performed on 48 eyes of 24 patients. Surgeries in Group I were performed for MMV using the RayOne EMV IOL targeting emmetropia in dominant eyes (Group IA) and -0.70 diopter (D) myopia in non-dominant eyes (Group IB), while those in Group II were performed with the AcrySof
IQ PanOptix
TNFT00 IOL targeting emmetropia. After the surgeries, uncorrected and corrected distance, intermediate, and near distance visual acuities, contrast sensitivity measurements, and defocus curves were determined. Subjective evaluation was made with the National Eye Institute Visual Function Questionnaire (NEI VFQ-25). The groups were compared statistically.
Postoperative refraction mean spherical equivalent was -0.25±0.22 D, -0.67±0.33 D, and -0.16±0.31 D in the three groups, respectively. A statistical difference was identified in favor of Group IA for uncorrected distance vision and in favor of Group IB for near vision (p0.05). While contrast sensitivity was better in Group I at all spatial frequencies (p0.05). Photic complaints were significantly more common in Group II.
With the MMV technique, it was observed that enhanced monofocal lenses provided better visual acuity at all distances and less dysphotopsia than trifocal lenses, whereas trifocal lenses were better at providing independence from glasses. |
---|---|
ISSN: | 1300-0659 2149-8709 2149-8695 2149-8709 2147-2661 |
DOI: | 10.4274/tjo.galenos.2024.27805 |