The sensitivity of ECG contamination to surgical implantation site in brain computer interfaces

Brain sensing devices are approved today for Parkinson's, essential tremor, and epilepsy therapies. Clinical decisions for implants are often influenced by the premise that patients will benefit from using sensing technology. However, artifacts, such as ECG contamination, can render such treatm...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Brain stimulation 2021-09, Vol.14 (5), p.1301-1306
Hauptverfasser: Neumann, Wolf-Julian, Memarian Sorkhabi, Majid, Benjaber, Moaad, Feldmann, Lucia K., Saryyeva, Assel, Krauss, Joachim K., Contarino, Maria Fiorella, Sieger, Tomas, Jech, Robert, Tinkhauser, Gerd, Pollo, Claudio, Palmisano, Chiara, Isaias, Ioannis U., Cummins, Daniel D., Little, Simon J., Starr, Philip A., Kokkinos, Vasileios, Gerd-Helge, Schneider, Herrington, Todd, Brown, Peter, Richardson, R. Mark, Kühn, Andrea A., Denison, Timothy
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:Brain sensing devices are approved today for Parkinson's, essential tremor, and epilepsy therapies. Clinical decisions for implants are often influenced by the premise that patients will benefit from using sensing technology. However, artifacts, such as ECG contamination, can render such treatments unreliable. Therefore, clinicians need to understand how surgical decisions may affect artifact probability. Investigate neural signal contamination with ECG activity in sensing enabled neurostimulation systems, and in particular clinical choices such as implant location that impact signal fidelity. Electric field modeling and empirical signals from 85 patients were used to investigate the relationship between implant location and ECG contamination. The impact on neural recordings depends on the difference between ECG signal and noise floor of the electrophysiological recording. Empirically, we demonstrate that severe ECG contamination was more than 3.2x higher in left-sided subclavicular implants (48.3%), when compared to right-sided implants (15.3%). Cranial implants did not show ECG contamination. Given the relative frequency of corrupted neural signals, we conclude that implant location will impact the ability of brain sensing devices to be used for “closed-loop” algorithms. Clinical adjustments such as implant location can significantly affect signal integrity and need consideration. •Chronic embedded brain sensing promises algorithm-based neurostimulation, but algorithms can be impaired by artifacts.•Implant location can have relevant impact on neural signal fidelity; simple models can provide guidance on the sensitivity.•ECG artifacts are present in up to 50% of neural signals from left subclavicular DBS systems.•Implanting DBS in a right subclavicular location significantly reduces frequency of ECG artifacts.•Cranial-mounted implants are relatively immune to artifacts.
ISSN:1935-861X
1876-4754
DOI:10.1016/j.brs.2021.08.016