Safety and efficacy of the Yamane technique for intraocular three-piece lens implantation in Egyptian patients diagnosed with Marfan syndrome: a retrospective study

This study aimed to investigate the safety and efficacy of the Yamane technique (flanged intrascleral haptic fixation with double-needle technique /FIHFT) for three-piece intraocular lens (IOL) implantation in Egyptian patients diagnosed with Marfan syndrome (MFS) presented with subluxated lenses (e...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:BMC ophthalmology 2024-11, Vol.24 (1), p.480-10, Article 480
Hauptverfasser: Elsalhy, Fathy Mohamed Abo Elftouh, Assaf, Ahmed Hassan Samir, Alshamarti, Sarah Abbas, Soliman, Noha Fawky, Khattab, Abdelrahman Ahmed Ali, Khalil, Mahmoud Mohammed Ahmed Ali, Morsy, Mahmoud Fawzy Zaky, Ibrahim, Ezzat Nabil Abbas, Abdul Hay, Ahmad Mohammad Salah Eldeen, Abouzeid, Mohamed Sayed Taha
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:This study aimed to investigate the safety and efficacy of the Yamane technique (flanged intrascleral haptic fixation with double-needle technique /FIHFT) for three-piece intraocular lens (IOL) implantation in Egyptian patients diagnosed with Marfan syndrome (MFS) presented with subluxated lenses (ectopia lentis, EL). This was a retrospective evaluation of thirty-three patients who were diagnosed with MFS and had subluxated lenses in a total of forty eyes. Seven of these patients had bilateral subluxation. Lensectomy or phacoemulsification was performed with limited anterior vitrectomy, followed by IOL implantation using the FIHFT method. Data was collected from medical records, including preoperative and postoperative corrected distant visual acuity (CDVA) using logarithm of the minimal angle of resolution (log MAR), preoperative and postoperative refractions, intraoperative and postoperative complications, and follow-up periods. The mean age of patients in the study was 30.79 years, with a mean follow-up of 23.9 months. Post-surgery, the refractive sphere decreased significantly from -9.1 ± 1.4 diopter (D) to -1.4 ± 0.7 D, and cylinder measurements dropped from -4.5 ± 0.8 D to -1.4 ± 0.6 D. The spherical equivalent (SEQ) also declined from -11.4 ± 1.5 D to -2.1 ± 0.8 D. The CDVA improved from 0.80 ± 0.32 to 0.18 ± 0.10 log MAR (P 
ISSN:1471-2415
1471-2415
DOI:10.1186/s12886-024-03724-y