Field performance test of an air-cleaner with photocatalysis-plasma synergistic reactors for practical and long-term use
A practical and long-term usable air-cleaner based on the synergy of photocatalysis and plasma treatments has been developed. A field test of the air-cleaner was carried out in an office smoking room. The results were compared to previously reported laboratory test results. Even after a treatment of...
Gespeichert in:
Veröffentlicht in: | Molecules (Basel, Switzerland) Switzerland), 2014-10, Vol.19 (11), p.17424-17434 |
---|---|
Hauptverfasser: | , , , , , , , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
Zusammenfassung: | A practical and long-term usable air-cleaner based on the synergy of photocatalysis and plasma treatments has been developed. A field test of the air-cleaner was carried out in an office smoking room. The results were compared to previously reported laboratory test results. Even after a treatment of 12,000 cigarettes-worth of tobacco smoke, the air-cleaner maintained high-level air-purification activity (98.9% ± 0.1% and 88% ± 1% removal of the total suspended particulate (TSP) and total volatile organic compound (TVOC) concentrations, respectively) at single-pass conditions. Although the removal ratio of TSP concentrations was 98.6% ± 0.2%, the ratio of TVOC concentrations was 43.8% after a treatment of 21,900 cigarettes-worth of tobacco smoke in the field test. These results indicate the importance of suitable maintenance of the reactors in the air-cleaner during field use. |
---|---|
ISSN: | 1420-3049 1420-3049 |
DOI: | 10.3390/molecules191117424 |