Comparison between visual inspection of turbidity and quantitative determination of triglycerides in plasma bags
ABSTRACT Introduction Blood donor screening is an important stage of quality control in blood banks. Turbidity caused by increased levels of triglycerides is detected by visual inspection, but there is no consensus on its threshold at which plasma should be considered inappropriate for donation. Obj...
Gespeichert in:
Veröffentlicht in: | Jornal brasileiro de patologia e medicina laboratorial 2022, Vol.58 |
---|---|
Hauptverfasser: | , , , , , |
Format: | Artikel |
Sprache: | eng ; por |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
Zusammenfassung: | ABSTRACT Introduction Blood donor screening is an important stage of quality control in blood banks. Turbidity caused by increased levels of triglycerides is detected by visual inspection, but there is no consensus on its threshold at which plasma should be considered inappropriate for donation. Objective Compare triglycerides dosage and visual turbidity in decision making for the disposal of plasma. Material and methods Plasma bags (n=205) were classified by visual inspection as clear, moderately turbid or turbid and triglyceride concentration were determined in serum and plasma with enzimatic-colorimetric methodology by automation. Results Our results show a positive correlation between serum and plasma triglycerides levels (r=0,94) but we observed a higher concentration in serum when compared to plasma samples (p |
---|---|
ISSN: | 1678-4774 1678-4774 |
DOI: | 10.1900/jbpml.2022.58.421 |