Risk Factor Analyses for the Return of Spontaneous Circulation in the Asphyxiation Cardiac Arrest Porcine Model

Background: Animal models of asphyxiation cardiac arrest (ACA) are frequently used in basic research to mirror the clinical course of cardiac arrest (CA). The rates of the return of spontaneous circulation (ROSC) inACA animal models are lower than those from studies that have utilized ventricular fi...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Chinese medical journal 2015-04, Vol.128 (8), p.1096-1101
Hauptverfasser: Wu, Cai-Jun, Guo, Zhi-Jun, Li, Chun-Sheng, Zhang, Yi, Yang, Jun
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:Background: Animal models of asphyxiation cardiac arrest (ACA) are frequently used in basic research to mirror the clinical course of cardiac arrest (CA). The rates of the return of spontaneous circulation (ROSC) inACA animal models are lower than those from studies that have utilized ventricular fibrillation (VF) animal models. The purpose of this study was to characterize the factors associated with the ROSC in the ACA porcine model. Methods: Forty-eight healthy miniature pigs underwent endotracheal tube clamping to induce CA. Once induced, CA was maintained untreated for a period of 8 min. Two minutes following the initiation of cardiopulmonary resuscitation (CPR), defibrillation was attempted until ROSC was achieved or the animal died. To assess the factors associated with ROSC in this CA model, logistic regression analyses were performed to analyze gender, the time of preparation, the amplitude spectrum area (AMSA) from the beginning of CPR and the pH at the beginning of CPR. A receiver-operating characteristic (ROC) curve was used to evaluate the predictive value ofAMSA for ROSC. Results: ROSC was only 52.1% successful in this ACA porcine model. The multivariate logistic regression analyses revealed that ROSC significantly depended on the time of preparation, AMSA at the beginning of CPR and pH at the beginning of CPR. The area under the ROC curve in for AMSA at the beginning of CPR was 0.878 successful in predicting ROSC (95% confidence intervals: 0.773-0.983), and the optimum cut-offvalue was 15.62 (specificity 95.7% and sensitivity 80.0%). Conclusions: The time of preparation, AMSA and the pH at the beginning of CPR were associated with ROSC in this ACA porcine model. AMSA also predicted the likelihood of ROSC in this ACA animal model.
ISSN:0366-6999
2542-5641
DOI:10.4103/0366-6999.155106