sEMG-Based Gain-Tuned Compliance Control for the Lower Limb Rehabilitation Robot during Passive Training

The lower limb rehabilitation robot is a typical man-machine coupling system. Aiming at the problems of insufficient physiological information and unsatisfactory safety performance in the compliance control strategy for the lower limb rehabilitation robot during passive training, this study develope...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Sensors (Basel, Switzerland) Switzerland), 2022-10, Vol.22 (20), p.7890
Hauptverfasser: Tian, Junjie, Wang, Hongbo, Zheng, Siyuan, Ning, Yuansheng, Zhang, Xingchao, Niu, Jianye, Vladareanu, Luige
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:The lower limb rehabilitation robot is a typical man-machine coupling system. Aiming at the problems of insufficient physiological information and unsatisfactory safety performance in the compliance control strategy for the lower limb rehabilitation robot during passive training, this study developed a surface electromyography-based gain-tuned compliance control (EGCC) strategy for the lower limb rehabilitation robot. First, the mapping function relationship between the normalized surface electromyography (sEMG) signal and the gain parameter was established and an overall EGCC strategy proposed. Next, the EGCC strategy without sEMG information was simulated and analyzed. The effects of the impedance control parameters on the position correction amount were studied, and the change rules of the robot end trajectory, man-machine contact force, and position correction amount analyzed in different training modes. Then, the sEMG signal acquisition and feature analysis of target muscle groups under different training modes were carried out. Finally, based on the lower limb rehabilitation robot control system, the influence of normalized sEMG threshold on the robot end trajectory and gain parameters under different training modes was experimentally studied. The simulation and experimental results show that the adoption of the EGCC strategy can significantly enhance the compliance of the robot end-effector by detecting the sEMG signal and improve the safety of the robot in different training modes, indicating the EGCC strategy has good application prospects in the rehabilitation robot field.
ISSN:1424-8220
1424-8220
DOI:10.3390/s22207890