A whole control strategy for cascaded H‐bridge rectifiers under distorted grid voltage and unbalanced load
Control for single‐phase cascaded H‐bridge rectifier (CHBR) under distorted grid voltage is seldom discussed in the existing control methods; a modified direct power control (DPC) scheme is therefore proposed in this paper. A simple power control structure with proportional‐integral control method i...
Gespeichert in:
Veröffentlicht in: | IET Power Electronics 2023-05, Vol.16 (7), p.1115-1127 |
---|---|
Hauptverfasser: | , , , , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
Zusammenfassung: | Control for single‐phase cascaded H‐bridge rectifier (CHBR) under distorted grid voltage is seldom discussed in the existing control methods; a modified direct power control (DPC) scheme is therefore proposed in this paper. A simple power control structure with proportional‐integral control method is first presented, which can discard phase‐locked loop (PLL) and coordinate transformation. Then, an improved fictitious orthogonal algorithm is proposed to provide a better anti‐disturbance ability compared with the traditional second‐order generalized integrator (SOGI). Since the orthogonal component of the grid current runs concurrently with the power reference, it offers an excellent dynamic performance in inner loop. On the other hand, a voltage balancing control (VBC) model by the relationship between the difference of dc‐side voltage square and that of power is established. On this basis, an internal model VBC (IM‐VBC) method is provided to reduce the parameter tuning complexity. With this method, the dynamic performance of voltage balancing on the dc side is improved. Finally, several test results on hardware‐in‐the‐loop (HIL) and scale‐down platform are demonstrated, which validate the effectiveness and superiority of the proposed control strategy.
Control for single‐phase cascaded H‐bridge rectifier (CHBR) under distorted grid voltage are seldom discussed in the existing control methods, a modified direct power control (DPC) scheme is therefore proposed in this paper. On the other hand, a voltage balancing control (VBC) model by the relationship between the difference of dc‐side voltage square and that of power is established. On this basis, an internal model VBC (IM‐VBC) method is provided to reduce the parameter tuning complexity. |
---|---|
ISSN: | 1755-4535 1755-4543 |
DOI: | 10.1049/pel2.12454 |