The diagnostic utility and cost-effectiveness of selective nerve root blocks in patients considered for lumbar decompression surgery: a systematic review and economic model
Diagnostic selective nerve root block (SNRB) involves injection of local anaesthetic, sometimes in conjunction with corticosteroids, around spinal nerves. It is used to identify symptomatic nerve roots in patients with probable radicular pain that is not fully concordant with imaging findings. (1) D...
Gespeichert in:
Veröffentlicht in: | Health technology assessment (Winchester, England) England), 2013-05, Vol.17 (19), p.1-88 |
---|---|
Hauptverfasser: | , , , , , , , , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
Zusammenfassung: | Diagnostic selective nerve root block (SNRB) involves injection of local anaesthetic, sometimes in conjunction with corticosteroids, around spinal nerves. It is used to identify symptomatic nerve roots in patients with probable radicular pain that is not fully concordant with imaging findings.
(1) Determine the diagnostic accuracy of SNRB in patients with low back and radiating pain in a lower limb; (2) evaluate whether or not accuracy varies by patient subgroups; (3) review injection-related adverse events; and (4) evaluate the cost-effectiveness of SNRB.
MEDLINE, EMBASE, Science Citation Index, Bioscience Information Service (BIOSIS), Latin American and Caribbean Health Sciences Literature (LILACS) and grey literature databases were searched from inception to August 2011. Reference lists of included studies were screened.
A systematic review (SR) of studies that assessed the accuracy of SNRB or adverse events in patients with low back pain and symptoms in a lower limb for the diagnosis of lumbar radiculopathy. Study quality was assessed using the quality assessment of diagnostic accuracy studies (QUADAS)-2 checklist. We used random-effects meta-analysis to pool diagnostic accuracy data. Decision tree and Markov models were developed, combining SR results with information on the costs and outcomes of surgical and non-surgical care. Uncertainty was assessed using probabilistic and deterministic sensitivity analyses.
Five studies assessed diagnostic accuracy: three diagnostic cohort and two within-patient case-control studies. All were judged to be at high risk of bias and had high concerns regarding applicability. In individual studies, sensitivity ranged from 57% [95% confidence interval (CI) 43% to 70%] to 100% (95% CI 76% to 100%) and specificity from 9.5% (95% CI 1% to 30%) to 86% (95% CI 76% to 93%). The most reliable estimate was judged to come from two cohort studies that used post-surgery outcome as the reference standard; summary sensitivity and specificity were 93% (95% CI 86% to 97%) and 26% (95% CI 5% to 68%), respectively. No study provided sufficient detail to judge whether or not accuracy varied by patient subgroup. Seven studies assessed adverse events. There were no major or permanent complications; minor complications were reported in 0-6% of patients. The addition of SNRB to the diagnostic work-up was not cost-effective with an incremental cost per quality-adjusted life-year of £1,576,007. Sensitivity analyses confirmed that SNRB was unl |
---|---|
ISSN: | 1366-5278 2046-4924 |
DOI: | 10.3310/hta17190 |