Cross-calibration of Chinese Gaofen-5 thermal infrared images and its improvement on land surface temperature retrieval

•The land surface temperature retrieval results were improved after cross-calibration.•A new split-window algorithm was proposed to verify the cross-calibration method.•The residuals of the split-window algorithm were optimized by the LightGBM method.•Validation was conducted using ground measure da...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:International journal of applied earth observation and geoinformation 2021-09, Vol.101, p.102357, Article 102357
Hauptverfasser: Ye, Xin, Ren, Huazhong, Liang, Yanzhen, Zhu, Jinshun, Guo, Jinxin, Nie, Jing, Zeng, Hui, Zhao, Yanhua, Qian, Yonggang
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:•The land surface temperature retrieval results were improved after cross-calibration.•A new split-window algorithm was proposed to verify the cross-calibration method.•The residuals of the split-window algorithm were optimized by the LightGBM method.•Validation was conducted using ground measure data and achieved good results. Thermal infrared (TIR) remote sensing technology is capable of acquiring large-scale land surface temperature (LST), which is a key factor in the energy exchange between land surface and atmosphere. The visible and infrared multispectral sensor (VIMS) equipped in the Chinese Gaofen-5 (GF-5) satellite can obtain four channels of TIR images with a 40 m spatial resolution. However, due to the change of working environment, the TIR sensor suffers a low-accurate radiometric calibration that needs improvement. This paper puts forward a new cross-calibration for GF-5/VIMS TIR images by linking the top of the atmosphere (TOA) radiance of the vertical angle MODIS observation with the GF-5/VIMS image to estimate the radiometric calibration coefficients, Gain and Offset. To verify the recalibration performance, a new nonlinear two-channel split-window (SW) algorithm and a light gradient boosting machine (LightGBM) method which is used to refine LST from the SW algorithm by minimizing the residuals, were developed for the recalibrated GF-5/VIMS TIR 3 and TIR 4 channels. The radiometric cross-calibration algorithm and the optimized SW algorithm were applied to real GF-5/VIMS TIR images. The validation results showed that the brightness temperature and LST were improved significantly, and the LST retrieval error was reduced greatly to 1.79 K after recalibration, indicating a large improvement of the LST retrieval for GF-5/VIMS TIR image using the proposed cross-calibration and SW algorithms.
ISSN:1569-8432
1872-826X
DOI:10.1016/j.jag.2021.102357