Manually prepared lamellae for Descemet stripping endothelial keratoplasty (Pachy-DSEK): comparison of four dissection depths
ABSTRACT Purpose: This study aimed to compare four depths of manual dissection for the preparation of Descemet stripping endothelial keratoplasty lamellae. Methods: Eye bank corneas were randomized into four groups according to dissection depths: Pachy-100 (incision depth = central corneal thickness...
Gespeichert in:
Hauptverfasser: | , , , , |
---|---|
Format: | Dataset |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext bestellen |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
Zusammenfassung: | ABSTRACT Purpose: This study aimed to compare four depths of manual dissection for the preparation of Descemet stripping endothelial keratoplasty lamellae. Methods: Eye bank corneas were randomized into four groups according to dissection depths: Pachy-100 (incision depth = central corneal thickness-safety margin of 100 µm), Pachy-50 (safety margin of 50 µm), Pachy-0 (no safety margin), and Pachy+50 (incision depth = central corneal thickness + 50 µm). All endothelial lamellae were prepared using a standardized method of manual dissection (Pachy-DSEK). The central, paracentral (3.0-mm zone), and peripheral (6.0-mm zone) lamella thicknesses and incision depths were measured by optical coherence tomography. The 3.0-mm and 6.0-mm zone central-to-peripheral thickness ratios were calculated. Results: Endothelial perforation occurred only in the Pachy+50 group (n=3, 30%). Central lamella’s thickness in Pachy-100, Pachy-50, Pachy-0, and Pachy+50 groups measured 185 ± 42 µm, 122 ± 29 µm, 114 ± 29 µm, and 58 ± 31 µm, respectively (p |
---|---|