Supplementary Material for: Defining the Validity of Skin Self-Examination as a Screening Test for the Detection of Suspicious Pigmented Lesions: A Meta-Analysis of Diagnostic Test Accuracy
Background: Skin self-examination (SSE) is widely promoted for the detection of suspicious pigmented lesions. However, determining screening accuracy is essential to appraising the usefulness of SSE. Objectives: The aim of this work was to pool estimates from studies of SSE diagnostic accuracy in th...
Gespeichert in:
Hauptverfasser: | , , , , , |
---|---|
Format: | Dataset |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext bestellen |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
Zusammenfassung: | Background: Skin self-examination (SSE) is widely promoted for the detection of suspicious pigmented lesions. However, determining screening accuracy is essential to appraising the usefulness of SSE. Objectives: The aim of this work was to pool estimates from studies of SSE diagnostic accuracy in the detection of suspicious pigmented lesions. Methods: This study was registered with PROSPERO (CRD42021246356) and conducted in accordance with PRISMA-DTA guidelines. A systematic search of Medline (PubMed) EMBASE, CINAHL, and The Cochrane Library was conducted to identify relevant studies. We included studies that examined the accuracy of SSE, either whole-body or site-specific, for detecting change in individual pigmented lesions or detecting an atypical naevus. A univariate random-effects model, based on logit-transformed data, was used to calculate a summary diagnostic odds ratio (DOR) as well as pooled sensitivity and specificity. Cochran’s Q test and the I2 statistic were calculated to assess heterogeneity. A proportional hazards model was used to calculate the area under the curve (AUC) and plot the summary receiver operator characteristic curve. We used the Quality Assessment of Diagnostic Accuracy Studies-2 tool to grade study quality. Results: We identified 757 studies, of which 3 met inclusion criteria for quantitative synthesis. The pooled sensitivity and specificity based on 553 included participants was 59 and 82%, respectively. The summary DOR was 5.88 and the AUC was 0.71. There were some concerns regarding risk of bias in all 3 studies. Conclusions: SSE can detect suspicious pigmented lesions with reasonable sensitivity and relatively high specificity, with the AUC suggesting acceptable discriminatory ability. |
---|---|
DOI: | 10.6084/m9.figshare.17714912 |