Lightning flashover simulations on medium voltage distribution lines

[Version 1.2] This version of the dataset fixes a bug found in the previous versions (see below for more information). Dataset has been generated from the Monte Carlo simulations of lightning flashovers on medium voltage (MV) distribution lines. It is suitable for training machine learning models fo...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
1. Verfasser: Sarajcev, P
Format: Dataset
Sprache:eng
Schlagworte:
Online-Zugang:Volltext bestellen
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:[Version 1.2] This version of the dataset fixes a bug found in the previous versions (see below for more information). Dataset has been generated from the Monte Carlo simulations of lightning flashovers on medium voltage (MV) distribution lines. It is suitable for training machine learning models for classifying lightning flashovers on distribution lines, as well as for line insulation coordination studies. The dataset is hierarchical in nature (see below for more information) and class imbalanced. Following five different types of lightning interaction with the MV distribution line have been simulated: (1) direct strike to phase conductor (when there is no shield wire present on the line), (2) direct strike to phase conductor with shield wire(s) present on the line (i.e. shielding failure), (3) direct strike to shield wire with backflashover event, (4) indirect near-by lightning strike to ground where shield wire is not present, and (5) indirect near-by lightning strike to ground where shield wire is present on the line. Last two types of lightning interactions induce overvoltage on the phase conductors by radiating EM fields from the strike channel that are coupled to the line conductors. Shield wire(s) provide shielding effects to direct, as well as screening effects to indirect, lightning strikes. Dataset consists of the following variables: 'dist': perpendicular distance of the lightning strike location from the distribution line axis (m), generated from the Uniform distribution [0, 500] m, 'ampl': lightning current amplitude of the strike (kA), generated from the Log-Normal distribution (see IEC 60071 for additional information), 'veloc': velocity of the lightning return stroke current (m/us), generated from the Uniform distribution [50, 500] m/us, 'shield': binary indicator that signals presence or absence of the shield wire(s) on the line (0/1), generated from the Bernoulli distribution with a 50% probability, 'Ri': average value of the impulse impedance of the tower's grounding (Ohm), generated from the Normal distribution (clipped at zero on the left side) with median value of 50 Ohm and standard deviation of 12.5 Ohm; it should be mentioned that the impulse impedance is often much larger than the associated grounding resistance value, which is why a rather high value of 50 Ohm have been used here, 'EGM': electrogeometric model used for analyzing striking distances of the distribution line's tower; following options are available: 'Wagner', 'Youn
DOI:10.5281/zenodo.6381636