Shot peening test rig test database

This database contains all the output extracted from the tests performed at polytechnique Montreal using the shot peening test rig developped by the Mëkanic company (http://www.mekanic.ca/) in the frame of the Ph.D. thesis of Simon Breumier (ORCID:https://orcid.org/0000-0003-3241-8383). The folder c...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Hauptverfasser: Breumier, Simon, Kermouche, Guillaume, Lévesque, Martin
Format: Dataset
Sprache:eng
Schlagworte:
Online-Zugang:Volltext bestellen
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:This database contains all the output extracted from the tests performed at polytechnique Montreal using the shot peening test rig developped by the Mëkanic company (http://www.mekanic.ca/) in the frame of the Ph.D. thesis of Simon Breumier (ORCID:https://orcid.org/0000-0003-3241-8383). The folder contains all the tests performed on Al6061 samples to : Estimate the canon shooting accuracy Estimate the relation between the canon pressure input and the shot velocity Estimate the coefficients of restitutions (CoR) The dataset contains the following folders: 0-5mm: tests performed using 0.5mm shot diameter to estimate the canon accuracy and pressure/velocity relation. All the tests were performed at the same position, therefore the velocity after impact is not a relevent data. 05mm_COR: tests performed using 0.5mm shot diameter to estimate the CoRs at different velocity. All the tests were performed at separated location so that no interaction between the shot dent occurs 1-19mm: tests performed using 1.19mm shot diameter to estimate the canon accuracy, the pressure/velocity relationship and the CoRs. All the tests were performed at separated location so that no interaction between the shot dent occurs. 2-5mm: tests performed using 2.5mm shot diameter to estimate the canon accuracy and the pressure/velocity. All the tests were performed at the same position, therefore the velocity after impact is not a relevent data. 2-5mm_COR: tests performed using 2.5mm shot diameter to estimate the CoRs at different velocity. All the tests were performed at separated location so that no interaction between the shot dent occurs Angles: tests performed usin 1.19mm shot diameter with different shooting angles. All the tests were performed at separated location so that no interaction between the shot dent occurs. Also, the cameras were recalibrated for each angular position. Each folder contains the different tests made for the three different shot diameters. For each diameter, each folder contains all the test performed at a given test pressure. Each pressure folder contains the folders containing the pictures taken by the left and top camera in tif format. For each pressure, the RESULTS folder containts the resulting trajectory extracted using the 3Deye software developped for the project (https://github.com/lm2-poly/3Deye). Among other things, the software provides a text file for each test summerizing the test conditions, the estimated trajectory, the cameras acquisition an
DOI:10.5281/zenodo.4001761