Nqrs Raw Data To Https://Doi.Org/10.1039/C8Cp03848A Table 1
These are the raw data files to the NQR measurements presented in https://doi.org/10.1039/C8CP03848A TABLE 1. T2 measurements were performed using spin echo sequence with variable echo time as explained section 3, Experimental details. T2 has been found by fitting a monoexponential decay. The best-f...
Gespeichert in:
Hauptverfasser: | , |
---|---|
Format: | Dataset |
Sprache: | eng |
Online-Zugang: | Volltext bestellen |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
Zusammenfassung: | These are the raw data files to the NQR measurements presented in https://doi.org/10.1039/C8CP03848A TABLE 1. T2 measurements were performed using spin echo sequence with variable echo time as explained section 3, Experimental details. T2 has been found by fitting a monoexponential decay.
The best-fit parameters for R2 = 1/T2 and FWHM can be found Table 1 in the column "experimental relaxation rate"
The names of the files follow the labelling: SampleName_transitionNr_temperture_sequence type.txt
the organization of the txt-files is as follows:
header: file source, number of frequency-points (Starting Point, End Point) and number of records (Starting 2D Record, Ending Record) = number of parameter sweeps (i.e. echo time)
Data set: records stacke on top of each other:
real part [a.u.] / imaginary part [a.u.] / frequency shift [kHz]
the frequency is given in difference from the central frequency (Obeserve Freq.), which can be found in the footer
footer: contains information on the used sequence and its paramteres. eg.g the "Obeserve Freq" of the spectrometer during the sequence, (excitiation and detection frequency)
also: filter bandwidth, dwell time, delay time, pulse length ...
the paramter "step size" of the sweep parameter (echo time or inversion time, respectively) is available on request: christian.goesweiner@tugraz.at |
---|---|