Data from: Use of a pressure-sensing walkway system for biometric assessment of gait characteristics in goats
The purpose of this study was to quantitatively assess gait characteristics and weight-bearing forces during ambulation in healthy goats using a pressure-sensing walkway as a biometric tool for stride, gait, and force analysis. Forty-six healthy adult goats ranging in age from 5 to 6 years, mixed-br...
Gespeichert in:
Hauptverfasser: | , , , , , , |
---|---|
Format: | Dataset |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext bestellen |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
Zusammenfassung: | The purpose of this study was to quantitatively assess gait
characteristics and weight-bearing forces during ambulation in healthy
goats using a pressure-sensing walkway as a biometric tool for stride,
gait, and force analysis. Forty-six healthy adult goats ranging in age
from 5 to 6 years, mixed-breeds, and with a mean body weight of 52 ± 7.1
kgs were used. Goats were trained to walk over a pressure-sensing walkway.
Data for analysis was collected on 2 different days, 3 days apart. On each
day, 2 to 5 walking passes, in the same direction, were captured for each
goat. Data from 2 valid passes meeting the criteria for consistent walking
gait on each day were averaged then used for analysis. Analysis was
performed, including the day-effect, for stride, gait, and force
characteristics. Of the 46 goats enrolled in the study, complete data sets
were achieved in 33 (72%) goats. Gait biometrics were similar among the
assessment days; therefore, all data was pooled for the purpose of
characterizing data for individual limb and biometric parameter
comparisons at the individual goat level. Statistical analysis revealed
that no difference within the paired limbs and that there were significant
differences between the front limbs and hind limbs. Maximum force and
maximum peak pressure were significantly greater for the front limbs as
compared with the hind limbs (p < 0.001). Based on the results,
gait and force characteristics can be consistently measured in goats using
a pressure-sensing walkway during a consistent walking gait. Goats apply
greater force to the forelimbs during the weight-bearing phase of stride
as compared with the hind limbs. The use of objective assessment tools is
expected to improve the ability of researchers and clinicians to monitor
changes in weight bearing and gait and will contribute to improved animal
welfare. |
---|---|
DOI: | 10.5061/dryad.72nj2d0 |