Data for: A Distal Start Point Facilitates Safer Insertion of S2 Iliac Screw Fixation
From January 2013 to November 2015, 36 consecutive patients (one 17-year-old pediatric patient and 35 adult patients above 20 years of age) received S2AI pelvic fixation using the freehand technique by a single surgeon. Among sixty-two S2AIs in 36 patients, there were 26 screws (42%) inserted in zon...
Gespeichert in:
1. Verfasser: | |
---|---|
Format: | Dataset |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext bestellen |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
Zusammenfassung: | From January 2013 to November 2015, 36 consecutive patients (one 17-year-old pediatric patient and 35 adult patients above 20 years of age) received S2AI pelvic fixation using the freehand technique by a single surgeon. Among sixty-two S2AIs in 36 patients, there were 26 screws (42%) inserted in zone A and 36 (58%) in zone B. There was no difference in demographics between the two groups (Table 2). There were 11 instrumentation breaches (three medial, eight lateral) of the iliac wing in zone A (42%) and 0 in zone B (p |
---|---|
DOI: | 10.17632/x8xhkd5wf3.1 |