Combined heat and moisture transfer in buildings systems

Temperature and humidity are the two main parameters indicating the comfort level of the building occupants. Although the effect of temperature is taken into account in thermal simulation of buildings, the moisture transfer through the rooms and porous building walls is sometimes neglected. The leve...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Hauptverfasser: Damle, Rashmin, Lehmkuhl Barba, Oriol, Rigola Serrano, Joaquim, Oliva Llena, Asensio
Format: Text Resource
Sprache:eng
Schlagworte:
Online-Zugang:Volltext bestellen
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:Temperature and humidity are the two main parameters indicating the comfort level of the building occupants. Although the effect of temperature is taken into account in thermal simulation of buildings, the moisture transfer through the rooms and porous building walls is sometimes neglected. The level of humidity can give different sensations of thermal comfort. It is necessary to take into account both heat and moisture transport in and around buildings to predict the hygrothermal behavior of rooms and building walls so as to calculate the energy demands correctly. In this work some benchmark exercises are worked out to see the performance of the heat and moisture transfer model implemented for rooms and porous walls. Finally, numerical results are compared with the measured data for a room exposed to varying outdoor conditions. Peer Reviewed