Atrial electromechanical coupling intervals in pregnant subjects : cardiovascular topic

Objective : The aim of this study was to evaluate atrial conduction abnormalities obtained by tissue Doppler imaging (TDI) and electrocardiogram analysis in pregnant subjects. Methods : A total of 30 pregnant subjects (28 ± 4 years) and 30 controls (28 ± 3 years) were included. Systolic and diastoli...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Cardiovascular Journal Of Africa 2014-02, Vol.25 (1), p.15-20
Hauptverfasser: Akkoy, Murat, Uysal, Ahmet, Altun, Burak, Gazi, Emine, Colkesen, Yucel, Tasolar, Hakan, Ozturk, Ufuk, Temiz, Ahmet, Barutcu, Ahmet, Acar, Gurkan, Gungor, Aysenur Cakir
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:Objective : The aim of this study was to evaluate atrial conduction abnormalities obtained by tissue Doppler imaging (TDI) and electrocardiogram analysis in pregnant subjects. Methods : A total of 30 pregnant subjects (28 ± 4 years) and 30 controls (28 ± 3 years) were included. Systolic and diastolic left ventricular (LV) function was measured using conventional echocardiography and TDI. Inter-atrial, intra-atrial and intra-left atrial electromechanical coupling (PA) intervals were measured with TDI. P-wave dispersion (PD) was calculated from a 12-lead electrocardiogram. Results : Atrial electromechanical coupling at the septal and left lateral mitral annulus (PA septal, PA lateral) was significantly prolonged in pregnant subjects (62.1 ± 2.7 vs 55.3 ± 3.2 ms, p < 0.001; 45.7 ± 2.5 vs 43.1 ± 2.7 ms, p < 0.001, respectively). Inter-atrial (PA lateral - PA tricuspid), intra-atrial (PA septum - PA tricuspid) and intra-left atrial (PA lateral - PA septum) electromechanical coupling intervals, maximum P-wave (Pmax) duration and PD were significantly longer in the pregnant subjects (26.4 ± 4.0 vs 20.2 ± 3.6 ms, p < 0.001; 10.0 ± 2.0 vs 8.0 ± 2.6 ms, p = 0.002; 16.4 ± 3.3 vs 12.2 ± 3.0 ms, p < 0.001; 103.1 ± 5.4 vs 96.8 ± 7.4 ms, p < 0.001; 50.7 ± 6.8 vs 41.6 ± 5.5 ms, p < 0.001, respectively). We found a significant positive correlation between inter-atrial and intra-left atrial electromechanical coupling intervals and Pmax (r = 0.282, p = 0.029, r = 0.378, p = 0.003, respectively). Conclusion : This study showed that atrial electromechanical coupling intervals and PD, which are predictors of AF, were longer in pregnant subjects and this may cause an increased risk of AF in pregnancy.
ISSN:1995-1892
1680-0745
DOI:10.5830/CVJA-2013-085