AVALIAÇÃO DA PRECISÃO DE DOIS SISTEMAS DE POSICIONAMENTO DE IMPLANTES GUIADOS EM DENSIDADES ÓSSEAS MEDULAR E CORTICAL: UM ESTUDO IN VITRO

Objective: The aim of the present study is to evaluate the accuracy of implant positioning with two different guided systems (milling and installation kits - with and without drill guides) in bone medullary and cortical densities. Materials and Methods: 40 conical prosthetic junction implants and 20...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:ARACÊ 2024-12, Vol.6 (4), p.15839-15856
Hauptverfasser: Giosa, Danielle Tallia, Chiavegatto, Diogo da Mota, Schröder, Julio César, Moro, Sidnei Antonio, Uhlendorf, Jean, Cardozo, Caio Gustavo Todesco, Thomé, Thiago Vieira, Miyasawa, Erton Massamitsu, Granjeiro, José Mauro, Fontão, Flávia Noemy Gasparini Kiatake
Format: Artikel
Sprache:por
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:Objective: The aim of the present study is to evaluate the accuracy of implant positioning with two different guided systems (milling and installation kits - with and without drill guides) in bone medullary and cortical densities. Materials and Methods: 40 conical prosthetic junction implants and 20 blocks of 40PFC and 10PFC dual-density polyurethane were used, simulating medullary and cortical bone, respectively, divided into four groups (Group 1 - System 1 with drill/medullary guide; Group 2 - System 1 with drill guide/Cortical; Group 3 - System 2 without drill/medullary guide; Group 4 - System 2 without drill guide/Cortical). The blocks were scanned and tomographed for digital planning. The implants were positioned through digital planning in each center of density, that is, two implants per block and each of the implants was positioned with 17º of inclination. Two different surgical guides were made for each instrumentation kit. After milling and implant installation, the scanbody was installed on the implants and the blocks were scanned again. The 3D image and the STL file generated from each block were superimposed on the initial virtual planning and the coronal, axial and angular deviation was calculated in the software for each implant. Objetivo: O objetivo do presente estudo é avaliar a precisão do posicionamento de implantes com dois diferentes sistemas guiados (kits de fresagens e instalação- com e sem guia de brocas) em densidades ósseas medular e cortical. Materiais e Métodos: Foram utilizados 40 implantes de junção protética cônica e 20 blocos de poliuretano de dupla densidade 40PFC e 10PFC, simulando osso medular e cortical respectivamente, divididos em quatro grupos (Grupo 1- Sistema 1 com guia de brocas/Medular; Grupo 2- Sistema 1 com guia de brocas/Cortical; Grupo 3- Sistema 2 sem guia de brocas/Medular; Grupo 4- Sistema 2 sem guia de brocas/Cortical). Os blocos foram escaneados e tomografados para planejamento digital. Os implantes foram posicionados através e planejamento digital em cada centro da densidade, ou seja, dois implantes por bloco e cada um dos implantes foi posicionado com 17o de inclinação. Foram realizadas duas guias cirúrgicas diferentes para cada kit de instrumentação. Após a fresagem e instalação dos implantes, foi instalado o scanbody nos implantes e os blocos foram escaneados novamente. A imagem 3D e o arquivo STL gerado de cada bloco, foi sobreposta ao planejamento virtual inicial e o desvio coronal, axial e angular
ISSN:2358-2472
2358-2472
DOI:10.56238/arev6n4-281