An Evoluation of Personal Dosimeter for Widely Distributed 134Cs and 137Cs by Using EGS Code

Personal dosimeters used at Fukushima et al. to measure exposure dose of individuals was studied by using electron photon Monte Carlo code EGS5. Personal dosimeters are used to measure the operation quantity, Hp(10). However, in the case of exposure from radionuclide like 134Cs or 137Cs distributed...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:RADIOISOTOPES 2013, Vol.62(6), pp.335-345
1. Verfasser: HIRAYAMA, Hideo
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:Personal dosimeters used at Fukushima et al. to measure exposure dose of individuals was studied by using electron photon Monte Carlo code EGS5. Personal dosimeters are used to measure the operation quantity, Hp(10). However, in the case of exposure from radionuclide like 134Cs or 137Cs distributed widely near the ground surface, photons enter to the human body with mainly slightly small angle than 90 degrees uniformly from all directions. From this study, it was found that the recorded dose in personal dosimeter was corresponding to equivalent dose as the results.
ISSN:0033-8303
1884-4111
DOI:10.3769/radioisotopes.62.335