Vertex distance variability of the Vision-S™ 700 refractors in normal population
ABSTRACT Objective: To study vertex-optical distance variation and estimate its impact on manifest refraction. Methods: Prospective study in a private clinic using the Vision-S™ 700 with five forehead positions. Forehead on the third position showed the closest vertex-optical distance of 12mm. Resul...
Gespeichert in:
Veröffentlicht in: | Revista Brasileira de Oftalmologia 2024, Vol.83 |
---|---|
Hauptverfasser: | , , , , , , , , , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
Zusammenfassung: | ABSTRACT Objective: To study vertex-optical distance variation and estimate its impact on manifest refraction. Methods: Prospective study in a private clinic using the Vision-S™ 700 with five forehead positions. Forehead on the third position showed the closest vertex-optical distance of 12mm. Results: Analysis of 52 eyes from 26 patients revealed mean differences in vertex-optical distance of 12.25mm (right eye) and 11.75mm (left eye). A 2mm change in vertex-optical distance resulted in a 0.05D change for a 5D spherical equivalent and 0.20D for a 10D equivalent. Conclusion: Vertex-optical distance varies among patients and is influenced by forehead adjustment. These variations impact refraction accuracy and treatment evaluation. Adjusting the forehead to the third position on the Vision-S™ 700 is recommended. |
---|---|
ISSN: | 0034-7280 1982-8551 |
DOI: | 10.37039/1982.8551.20240036 |