Can we improve the accuracy of electrocardiographic algorithms for accessory pathway location in children?
Predicting an accessory pathway location is extremely important in pediatric patients. We designed a study to compare previously published algorithms by Arruda, Boersma, and Chiang. This multicenter study included patients who had undergone successful ablation of one accessory pathway. Analysis of r...
Gespeichert in:
Veröffentlicht in: | Kardiologia polska 2022-01, Vol.80 (1), p.33-40 |
---|---|
Hauptverfasser: | , , , , , , , , , , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
Zusammenfassung: | Predicting an accessory pathway location is extremely important in pediatric patients.
We designed a study to compare previously published algorithms by Arruda, Boersma, and Chiang.
This multicenter study included patients who had undergone successful ablation of one accessory pathway. Analysis of resting 12-lead electrocardiograms was carried out. An aggregated prediction score was constructed on the basis of algorithm agreement, and a structured workflow approach was proposed.
The total population was 120 patients (mean age, 12.7 [± 3.6] years). The algorithm by Boersma had the highest accuracy (71.7%). The inter-rater agreement among the 3 reference algorithms, according to left-sided accessory pathway (AP) identification, was good between Boersma and Chiang (κ = 0.611; 95% confidence interval [CI], 0.468-0.753) but moderate between Arruda and Chiang and between Arruda and Boersma (κ = 0.566; 95% CI, 0.419-0.713 and κ = 0.582; 95% CI, 0.438-0.727, respectively). Regarding locations at risk of atrioventricular (AV) block, agreement was fair between Arruda and Chiang and between Boersma and Chiang (κ = 0.358; 95% CI, 0.195-0.520 and κ = 0.307; 95% CI, 0.192-0.422, respectively) but moderate between Arruda and Boersma (κ = 0.45; 95% CI, 0.304-0.597). On applying a first-step diagnostic evaluation, when concordance was achieved, we were able to correctly identify left-sided or non-left-sided ablation sites in 96.4% (n = 80) of cases. When concordance was achieved, correct prediction of risk/no risk of AV block was achieved in 92.2% (n = 59) of cases.
An aggregated prediction score based on 3 reference algorithms proved able to predict an accessory pathway location very precisely and could be used to plan safely invasive procedures. |
---|---|
ISSN: | 0022-9032 1897-4279 |
DOI: | 10.33963/KP.a2021.0167 |