Test read method using as-deposited MAMMOS media

To eliminate the time required for test data recording before test read, we studied test read approaches using as-deposited MAMMOS media, i.e., without recording the pre-determined test data onto the media. We consider the accumulation of the absolute values of this difference in the two moving aver...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Transactions of the Magnetics Society of Japan 2004/11/01, Vol.4(4-2), pp.156-159
Hauptverfasser: Imai, Susumu, Ido, Hiroshi, Tani, Manabu, Awano, Hiroyuki, Ishizaki, Osamu, Ota, Norio
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:To eliminate the time required for test data recording before test read, we studied test read approaches using as-deposited MAMMOS media, i.e., without recording the pre-determined test data onto the media. We consider the accumulation of the absolute values of this difference in the two moving averages as a good criterion to obtain desirable readout laser power. The results from our experiments suggest the proposed method is effective as long as the as-deposited conditions can be well-controlled.
ISSN:1346-7948
1884-6726
DOI:10.3379/tmjpn2001.4.156