Flow visualization and PIV measurement of flow in a bio-sensor cell
A water exchange process in a biosensor container was visualized using a laser fluorescence technique and measured using a PIV. The water exchange process needs optimizing in order to shorten the start up period and not to break lipid membrane. Numerical simulation was also conducted and results wer...
Gespeichert in:
Veröffentlicht in: | Journal of the Visualization Society of Japan 2005/07/01, Vol.25(Supplement1), pp.225-228 |
---|---|
Hauptverfasser: | , , , , , , |
Format: | Artikel |
Sprache: | jpn |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
Zusammenfassung: | A water exchange process in a biosensor container was visualized using a laser fluorescence technique and measured using a PIV. The water exchange process needs optimizing in order to shorten the start up period and not to break lipid membrane. Numerical simulation was also conducted and results were compared. Flow in a container is clarified and effect of flow rate is discussed. Qualitative agreement between experimental and numerical result is obtained. |
---|---|
ISSN: | 0916-4731 1346-5260 1884-037X |
DOI: | 10.3154/jvs.25.Supplement1_225 |