Dynamic Micro PIV Measurement of Transient Flow in Microfluidic Device
This paper reports a new technique of micro-resolution Particle Image Velocimetry (PIV). To investigate transient phenomena in a microfluidic device, a high-speed micro-PIV technique was developed by combining a high-speed camera and a continuous wave (CW) laser. The technique was applied to a micro...
Gespeichert in:
Veröffentlicht in: | Journal of the Visualization Society of Japan 2004/07/01, Vol.24(Supplement1), pp.39-42 |
---|---|
Hauptverfasser: | , , , , , |
Format: | Artikel |
Sprache: | jpn |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
Zusammenfassung: | This paper reports a new technique of micro-resolution Particle Image Velocimetry (PIV). To investigate transient phenomena in a microfluidic device, a high-speed micro-PIV technique was developed by combining a high-speed camera and a continuous wave (CW) laser. The technique was applied to a micro-counter-current flow, consisting of water and butyl acetate. The velocity fields of water in the micro counter-current flow were visualized for a time resolution of 500μs and a spatial resolution of 2.2 x 2.2 μm. Using the micro-PIV technique, the vortex-like motions of fluorescent particles around the water-butyl acetate interface were captured clearly. |
---|---|
ISSN: | 0916-4731 1346-5260 1884-037X |
DOI: | 10.3154/jvs.24.Supplement1_39 |