Estimates Of Glomerular Filtration Rate in Critically Ill Patients With Sepsis: Comparisons of Different Equations

Introduction: Accurate assessment of glomerular filtration rate (GFR) is important in the critically ill. Kinetic estimate of GFR (keGFR) considers the changes of creatinine, creatinine production rate, and volume of distribution, hence postulated to be a more accurate estimate of GFR, where there a...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:International medical journal Malaysia 2022-04, Vol.21 (2)
Hauptverfasser: Md Ralib, Azrina, Mohd Hanafiah, Farah Nadia, Abd Rashid, Iqbalmunawwir, Abd Rahim, Shahir Asraf, Mat Nor, Mohd Basri
Format: Artikel
Sprache:eng
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:Introduction: Accurate assessment of glomerular filtration rate (GFR) is important in the critically ill. Kinetic estimate of GFR (keGFR) considers the changes of creatinine, creatinine production rate, and volume of distribution, hence postulated to be a more accurate estimate of GFR, where there are rapidly changing kidney functions. We evaluated the association of the estimated GFR by established equations and keGFR with creatinine clearance (CrCl) measurement. Materials and Methods: This is a prospective observational study of critically ill patients. Inclusion criteria were patients older than 18 years old with sepsis (clinical infection and increase in SOFA score>2), and plasma procalcitonin>0.5ng/ml. Plasma creatinine and Cystatin C (CysC) were measured on admission and 4 hours later, and the eGFR were calculated by the Cockcroft Gault (CG), MDRD, CKD-EPI and keGFR equations, and compared to the CrCl measurement. Results: A total of 70 patients were recruited. eGFR by all 4 equations strongly correlates with CrCl. keGFR had the least bias depicted by the mean differences nearest to zero (-18ml/min). Similarly, keGFRCysC had less bias than eGFRCysC, with mean difference of -21ml/min. eGFRCG had the greatest precision depicted by the narrower SD lines, however the precision of both keGFR were not much difference compared to those of eGFRCG. Conclusions: In critically ill patients with sepsis, keGFRCr and keGFRCysC had the least bias and fair precision when compared to creatinine clearance measurement. In the absence of creatinine clearance measurement, keGFR calculations is useful as surrogate for kidney function.
ISSN:1823-4631
1823-4631
DOI:10.31436/imjm.v21i2.1980