RESEARCH ON THE DIAGNOSTIC ACCURACY OF THE TILE FINISH EXTERNAL WALL BY VARIOUS MEASURING METHODS

In this research, it experimented in exterior wall diagnosis using the trial examination object which created the exfoliation part of the outer wall artificially for the purpose of grasping the tendency about the detection accuracy and the measuring limit of the defective part for every diagnosis me...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:AIJ Journal of Technology and Design 2015/10/20, Vol.21(49), pp.919-924
Hauptverfasser: MAKATAYAMA, Miho, TANANO, Hiroyuki, NEMOTO, Kaori
Format: Artikel
Sprache:eng ; jpn
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:In this research, it experimented in exterior wall diagnosis using the trial examination object which created the exfoliation part of the outer wall artificially for the purpose of grasping the tendency about the detection accuracy and the measuring limit of the defective part for every diagnosis method. As a result, the thickness of the defective part and the size of the defect, it will vary depending investigation techniques such as an infrared inspection or a test hammer inspection by an inspector, there is a clear difference in the extent of degradation diagnosis can be revealed.
ISSN:1341-9463
1881-8188