EXPERIMENTAL STUDY ON BOND STRENGTH BETWEEN CERAMIC TILE AND PRECAST CONCRETE COLUMN USING 150MPa CONCRETE(Materials and Construction)

Precast columns using 150MPa concrete were produced, and bond strength of the ceramic tile was investigated. As a result, the following conclusions were obtained. (1) Bond strength of tile in 150 MPa concrete column was higher than that of 60 MPa concrete column. (2) Bond strength of most tiles was...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:AIJ Journal of Technology and Design 2006/12/20, Vol.12(24), pp.15-20
Hauptverfasser: KUBOTA, Hiroshi, JINNAI, Hiroshi, KUROIWA, Shusuke, WATANABE, Satoshi, TERAUCHI, Rieko, SHIMONO, Mitsuo, HATTORI, Atsushi, TERASHIMA, Tomohiro
Format: Artikel
Sprache:eng ; jpn
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:Precast columns using 150MPa concrete were produced, and bond strength of the ceramic tile was investigated. As a result, the following conclusions were obtained. (1) Bond strength of tile in 150 MPa concrete column was higher than that of 60 MPa concrete column. (2) Bond strength of most tiles was high enough compared with a regulated value. (3) It was useful for the improvement of bond strength to paint the acrylic silicon resin on the backside of the tile. (4) The direction of the back foot did not influence bond strength of the tile.
ISSN:1341-9463
1881-8188
DOI:10.3130/aijt.12.15_2