EFFECT OF INCORPORATING ORGANIC AND STEEL FIBER ON FIRE RESISTANCE OF 80 TO 200N/mm2 HIGH STRENGTH CONCRETE COLUMNS
Fire resistance of High strength reinforced concrete columns with specified design strength of 80N/mm2 to 200N/mm2 were conducted by loaded fire resistance tests. High strength concrete column without fiber showed explosive spalling and fire resisting period of columns were less than 2 hours. Incorp...
Gespeichert in:
Veröffentlicht in: | Journal of Structural and Construction Engineering (Transactions of AIJ) 2010/02/28, Vol.75(648), pp.461-468 |
---|---|
Hauptverfasser: | , , , |
Format: | Artikel |
Sprache: | eng ; jpn |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
Zusammenfassung: | Fire resistance of High strength reinforced concrete columns with specified design strength of 80N/mm2 to 200N/mm2 were conducted by loaded fire resistance tests. High strength concrete column without fiber showed explosive spalling and fire resisting period of columns were less than 2 hours. Incorporating polypropylene fiber to concrete of 150N/mm2 or less was showned to be effective for preventing spalling of concrete and prolonging fire resisting period. For more than 180N/mm2 columns, 0.33vol% of polypropylene fiber were not sufficient for preventing explosive spalling and incorporating both polypropylene and steel fiber enables to maintain 3 hours of fire resistive period. |
---|---|
ISSN: | 1340-4202 1881-8153 |
DOI: | 10.3130/aijs.75.461 |