Optical loss of metal coated optical fibers at temperatures up to 800°C

Temperature band of ordinary telecommunication optical fibers is −60...85°C. The developing fiber optic sensors which can work at higher temperatures, required to develop metal coated optical fibers. The Purpose of the work is a researching additional optical loss of copper alloy coated optical fibe...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Optical memory & neural networks 2012-03, Vol.21 (1), p.45-51
Hauptverfasser: Popov, S. M., Voloshin, V. V., Vorobyov, I. L., Ivanov, G. A., Kolosovskii, A. O., Isaev, V. A., Chamorovskii, Y. K.
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:Temperature band of ordinary telecommunication optical fibers is −60...85°C. The developing fiber optic sensors which can work at higher temperatures, required to develop metal coated optical fibers. The Purpose of the work is a researching additional optical loss of copper alloy coated optical fibers which were drawn from low hydroxyl group contamination preforms at temperatures 20...800°C. It is reached that metal coated optical fiber worked at temperature 700°C for 7 hours, while the optical losses changed from 2 to 3 dB/km at the wavelength of λ = 1300 nm. It is not observed intensive growth of optical losses on hydroxyl groups at 800°C, which was observed in metal coated optical fiber when it was heated at 700°C.
ISSN:1060-992X
1934-7898