Calculations for a woven electrical heater with a uniform temperature distribution on its surface
There exists a problem of local overheating when heating the flat surfaces of objects with woven electrical heaters with a nonuniform thermal field. A method for determining the location of high-resistance filaments in the heater, which provides more uniform distribution of thermal field, was propos...
Gespeichert in:
Veröffentlicht in: | Journal of machinery manufacture and reliability 2011-12, Vol.40 (6), p.573-578 |
---|---|
Hauptverfasser: | , , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
Zusammenfassung: | There exists a problem of local overheating when heating the flat surfaces of objects with woven electrical heaters with a nonuniform thermal field. A method for determining the location of high-resistance filaments in the heater, which provides more uniform distribution of thermal field, was proposed for the purpose of obtaining a more uniform temperature field. Results can be used by professionals involved in the creation and operation of woven heaters, water capillary heaters, and various kinds of filament heaters. |
---|---|
ISSN: | 1052-6188 1934-9394 |
DOI: | 10.3103/S1052618811060161 |