Fundamental study of artificial synaptic model

An artificial synaptic model was constructed by assembling an actuator and a sensor. The actuator was consist of a square pipe cell with two carbon electrodes. The actuator was filled with acrylic acid gel microparticles swelled with glucose solution which were shrunken under an electric field. The...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Journal of Advanced Science 1997/06/30, Vol.9(1-2), pp.91-92
Hauptverfasser: OHTA, Yoshihisa, SETO, Masaya, IWAMOTO, Kazutoshi, YODA, Kentaro
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:An artificial synaptic model was constructed by assembling an actuator and a sensor. The actuator was consist of a square pipe cell with two carbon electrodes. The actuator was filled with acrylic acid gel microparticles swelled with glucose solution which were shrunken under an electric field. The sensor was a glucose sensor which was constructed by combining an oxygen electrode with an immobilized glucose oxidase membrane. The out put current of glucose sensor in the synaptic model was observed under the application of DC field to the actuator. The amount of glucose released from the actuator increased time-dependently with increasing voltage above 5V, however, little release was observed below 5V.
ISSN:0915-5651
1881-3917
DOI:10.2978/jsas.9.91