Limit of Application of Breed Method and Relationship between Individual Bacterial Counts measured by Breed Method and Colony Counts measured by Standard Plate Count Method

The limit of the application of the Breed method and the relationship between the direct microscopic counts of individual bacteria measured by the Breed method and the bacterial populations measured by the standard plate count (SPC) method was examined, using the data obtained in the performance tes...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Nihon Chikusan Gakkaiho 1987/12/25, Vol.58(12), pp.1048-1053
Hauptverfasser: YOSHINO, Masazumi, SATO, Tetsuo, KITADA, Tokuzou, FURUKAWA, Sakon, SOMEYA, Yukio, HASHIZUME, Kazumoto, MORICHI, Toshiki
Format: Artikel
Sprache:jpn
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:The limit of the application of the Breed method and the relationship between the direct microscopic counts of individual bacteria measured by the Breed method and the bacterial populations measured by the standard plate count (SPC) method was examined, using the data obtained in the performance test of Bactoscan 17600 (A/S N. Foss Electric, Denmark). The correlation coefficient between the logarithm values obtained by the Breed method and those of Bactoscan Impulses were 0.491 for the samples whose Bactoscan Impulses were less than 1000.This shows that the Breed method was unrelialiable for the samples of low bacterial counts (
ISSN:1346-907X
1880-8255
DOI:10.2508/chikusan.58.1048