Air Exchange Rate in Air Quality Assurance – A Case Study

The goals of this paper are to estimate some parameters – indoor temperature and ventilation rate - necessary to determine the heat load demand for ventilation in the amphitheatre named ‘A TALPOSI’-Faculty of Buildings Engineering- with a number of at the most 120 occupants. The study presented in t...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Journal of Applied Engineering Sciences 2018-05, Vol.8 (1), p.13-18
Hauptverfasser: Cîrstolovean, I. L., Horneț, M., Ancas, Ana Diana, Profire, M.
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:The goals of this paper are to estimate some parameters – indoor temperature and ventilation rate - necessary to determine the heat load demand for ventilation in the amphitheatre named ‘A TALPOSI’-Faculty of Buildings Engineering- with a number of at the most 120 occupants. The study presented in this paper is made when in the amphitheatre it is necessary to assure a comfortable temperature by a permanent functioning of the heating system. The number of air exchanges necessary in the amphitheatre in the natural ventilation process, more exactly, to assure a minimum air exchanges, is imposed by the requirements for the assurance of physiologic comfort in the amphitheatre for the time interval when it is occupied by students. The inner air debit should cover the harmful emissions in the amphitheatre. By the help of these calculated (measured) parameters we have calculated the heat load for ventilation. In the end, with the data obtained from calculations and measurements we find ourselves in the situation of establishing the size of the heat exchanger corresponding to the room, to heat the fresh air taken from outside and send it inside the amphitheatre. The measurements are made with the TESTO apparatus of the faculty. The minimum requirements to assure the thermal comfort are: to achieve a minimum internal temperature θi (t) higher than (or equal to) the normal indoor temperature associated to this space and to assure the air quality, the air exchange rate. The authors want to highlight by this study the necessity and importance of the control on the number of air exchanges in rooms with a high number of occupants and overall, the control of the fresh air debits. The fact that the focus is more and more on heat loss cuts in rooms by tightening closing elements gives birth to the necessity of control of the ventilation system with effects on the consumption of mechanical energy.
ISSN:2247-3769