Proximal Tibial Epiphysiodesis in a Growing Dog

 Background: It is believed that the inclined tibial plateau angle to be a major cause of cranial cruciate ligament (CCL) rupture, and the treatment of this disease is the tibial plateau leveling for decrease the cranial tibial thrust. However, there are breeds predisposed to rupture of the cranial...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Acta scientiae veterinariae 2016-01, Vol.44 (1), p.4
Hauptverfasser: Mesquita, Luciane Dos Reis, Muzzi, Leonardo Augusto Lopes, Giannico, Amália Turner, Muzzi, Ruthnéa Aparecida Lázaro, Monteiro, Juliana Fonseca, Brienza, Paula Desjardins
Format: Artikel
Sprache:eng
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung: Background: It is believed that the inclined tibial plateau angle to be a major cause of cranial cruciate ligament (CCL) rupture, and the treatment of this disease is the tibial plateau leveling for decrease the cranial tibial thrust. However, there are breeds predisposed to rupture of the cranial cruciate ligament and in this patterns breed the tibial plateau is more in­clined due to the conformation of the limb. The aim of this communication was to evaluate the effectiveness of the locking screw and cauterizing the growth plate of the tibial plateau as a preventive method of cranial cruciate ligament rupture. Case: In a young dog, one stifle joint randomly chosen for placing a screw in order to block the tibial plateau growth line. There was placed a 3.5 mm x 20 mm cancellous bone screw in the dorsocranial surface of the tibial plateau of the left hindlimb. Two months after the first surgical intervention, the contralateral limb was cauterized in the tibial plateau growth line. Electrocauterization was performed with a spatula electrode set at 60 watts, performing ablation on the cra­nial third of the tibial plateau physis with access to the medial and lateral surfaces of the proximal tibia. The electrode was placed against the physis for 10 seconds at each site. Both members were followed radiographically to measure the tibial plateau angle and observed the angle reduction. After 30 and 60 days post-surgery, the tibial plateau angle in left hindlimb decreased to 11o and -4o, respectively. However, the decrease plateau tibial angle was intense and severe and the screw was removed of the bone. However, even with the proximal tibial physis still open, withdrawing the screw did not alter the tibial plateau angle, which remained at -4º until the animal reached adulthood. The right left hindlimb was used as a control until the dog was 6 months old, when the tibial plateau angle exhibited a 26°. With the electrocauterization technique the tibial plateau angle decreased to 18° and 16° at 30 and 60 days after surgery, respectively, remaining at this last value until the animal completed its growth. Discussion: In the animals with cranial cruciate ligament rupture is indicate same surgical procedures like tibial plateau leveling osteotomy. In these cases, the recommended tibial plateau angle is aproximattely 5o. This study sought to block the line of growth of the tibial plateau to be reached an angle of approximately 5o. Epiphysiodesis technique with screw was
ISSN:1679-9216
1679-9216
DOI:10.22456/1679-9216.84520