A Prospective Evaluation of a Nurse-Led Stent Removal Service Using the Single-Use Isiris®in a Tertiary Referral Stone Unit and its Impact on Patient Waiting Times
Background and Objective Double J (JJ) ureteric stenting represents one of the most significant causes of patient discomfort and dissatisfaction following endourological procedures. At our institution, a large tertiary referral centre for complex stones, standard JJ stent removal was previously unde...
Gespeichert in:
Veröffentlicht in: | Journal of Endoluminal Endourology 2021-01, Vol.4 (1), p.e45-e53 |
---|---|
Hauptverfasser: | , , , , , , , |
Format: | Artikel |
Sprache: | eng |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
Zusammenfassung: | Background and Objective
Double J (JJ) ureteric stenting represents one of the most significant causes of patient discomfort and dissatisfaction following endourological procedures. At our institution, a large tertiary referral centre for complex stones, standard JJ stent removal was previously undertaken with a flexible cystoscope (FC) in the endoscopy department by a doctor. The pathway was prone to delays through capacity constraints and prioritization being given to cancer investigations. The Isiris® is a single-use stent removal system consisting of a ‘camera on chip’ disposable FC with an integrated grasper. We examine the feasibility of a nurse-led stent removal service using Isiris®, performed as an office-based procedure, and its effect on waiting times.
Material and Methods
A specialist stone nurse undertook training in FC approved by the British Association of Urological Surgeons (BAUS) and the British Association of Urological Nurses (BAUN). Once competency was reached, a nurseled service was offered to patients in the outpatient setting. A prospective database from April 2018 to March 2020 was maintained to include patient data for stent removals in the nurse-led clinic using Isiris®. This was compared to a retrospective dataset of FC and stent removal between July 2016 and December 2016, performed by a doctor in the endoscopy department. The delays in stent removal compared to the ‘ideal’ stent removal date (planned date plus or minus 3 days tolerance allowed) were compared between the two pathways.
Results
The specialist nurse undertook BAUS theory training and competency was reached using an approved BAUS/BAUN competency package. 414 stent removals were booked in the nurse group, of which 395 were undertaken. 291 of 395 (74%) patients in the nurse removal Isiris® group had their stent removed on time, whereas only 16 of 54 (30%) patients had their stents removed on time in the FC stent removal group. A delay of more than 21 days was seen in 22% of FC group vs only 2% in the nurse-led Isiris® group. Both planned removal and actual stent dwell time were longer in the FC group compared to Isiris® group (p < 0.0001). There were no major complications with the use of Isiris® for stent removal in the nurse-led clinic.
Conclusion
This study has demonstrated that it is feasible to introduce a nurse-led stent removal service. The introduction of this service using the Isiris® system has led to a reduction in delays of stent removal, which is likely |
---|---|
ISSN: | 2561-9187 2561-9187 |
DOI: | 10.22374/jeleu.v4i1.90 |