Isolation and Identification of Bacteria from Electronic devices used by Students and Staffs in Ines Ruhengeri

Background: Electronic devices have become one of the most essential accessories being used in daily lives including schools. Those devices increase the communication and using them makes learning much easier. Microbial contamination of electronic devices and inanimate surface of electronic equipmen...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Journal of drug delivery and therapeutics 2024-06, Vol.14 (6), p.131-137
Hauptverfasser: Jean Pierre, UWIZEYIMANA, ALAIN PRUDENCE, ISHIMWE, Innocent, NZABANTERURA, Ezechiel, BIZIMANA, Chrysostome, UWIHANGANYE Jean, Jean de Dieu, Ndayambaje, Godefroid, NZEYIMANA, Jean Polycarpe Delphin, IRAKOZE
Format: Artikel
Sprache:eng
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:Background: Electronic devices have become one of the most essential accessories being used in daily lives including schools. Those devices increase the communication and using them makes learning much easier. Microbial contamination of electronic devices and inanimate surface of electronic equipment at INES-Ruhengeri can have a significant role for transmission of pathogenic bacteria. Aim: The aim of this study was to isolate and identify bacteria from electronic devices used by students and staffs at INES-Ruhengeri University. Methodology: This cross-sectional study was done on 40 electronic devices such as computers, microscopes, global positioning system (GPS) and total stations A random sampling method was applied from sterile swab soaked in peptone water solution by the technique of bearing on the surface of the entire devices and then placed in a transport medium. Collected samples were then taken in INES-Ruhengeri Microbiology laboratory for further experiments. Results: All 40 electronic devices were contaminated with bacteria. The most predominant bacteria isolated from electronic devices was S.aureus (25.9%) followed by Bacillus spp(24.1%), K.pneumonia(12.9%), S.epidermis(12.9%), Micrococcus spp(7.4%), P.aeruginosa(5.5%), E.coli(3.3%), Salmonella spp(3.3%) and Shigella spp(3.3%). Antimicrobial susceptibility pattern of selected antibiotics was performed. Norfloxin was the most sensitive antibiotic on all isolated bacteria. Chloramphenicol antibiotic shown no activity over any of the isolated bacteria, to imply that all bacteria had resistance on it.  Conclusion: This study shown that there is bacterial contamination to all devices and antibiotic susceptibility test shown that some antibiotics were sensitive and resistant to the isolated bacteria.
ISSN:2250-1177
2250-1177
DOI:10.22270/jddt.v14i6.6650