Seismic Response Control of a Soft First-Story Building

A structure with a building plane 7.75 × 8.35 m, 47.8 m high, and having a height/width aspect ratio exceeding 6 has a building response that is difficult to control in both seismic and wind loading. We therefore changed the vibration mode from rocking to swaying by softening first-story translation...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Journal of disaster research 2009-06, Vol.4 (3), p.239-245
Hauptverfasser: Hayabe, Yasuhiro, Watanabe, Yuichi
Format: Artikel
Sprache:eng
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:A structure with a building plane 7.75 × 8.35 m, 47.8 m high, and having a height/width aspect ratio exceeding 6 has a building response that is difficult to control in both seismic and wind loading. We therefore changed the vibration mode from rocking to swaying by softening first-story translation stiffness and concentrating building deformation to make the first story energy-absorbing. The soft first-story structure we introduce involves (1) stiffening the structure above the second story, (2) making first-story columns laterally flexible and axially rigid, and (3) developing a response-hardening oil damper. The sections below detail these structural elements and dynamic response control performance against wind and seismic loading through time-history response analysis.
ISSN:1881-2473
1883-8030
DOI:10.20965/jdr.2009.p0239