Sanitary sewage disinfection of a municipal treatment plant: use of individual and combined ozonation with UVC-LED radiation
Abstract The systematic articulation of water resources involves the use of technical and management instruments capable of minimizing environmental impacts with optimization of available capital and constitution of sewage treatment plants (STPs) to seek greater efficiency in the removal of contamin...
Gespeichert in:
Veröffentlicht in: | Engenharia Sanitaria e Ambiental 2024, Vol.29 |
---|---|
Hauptverfasser: | , , , , |
Format: | Artikel |
Sprache: | eng ; por |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
Zusammenfassung: | Abstract The systematic articulation of water resources involves the use of technical and management instruments capable of minimizing environmental impacts with optimization of available capital and constitution of sewage treatment plants (STPs) to seek greater efficiency in the removal of contaminants, including microbiological ones, and enhance the quality of the water to be released into the receiving bodies. In systems where tertiary treatment is present, disinfection methods such as chlorination and UV radiation are commonly used as a final polishing of the effluent, and the monitoring of their effectiveness in disinfection is extremely important to avoid unnecessary expenses. Thus, this research sought to analyze the efficiency of disinfection of effluent samples from an STP of the sanitation system in the municipality of Indaial-SC using ozonation methods and the process combined with UVC-light-emitting diode (LED) radiation, on a bench scale, in batches. The determination of treatment efficiency was carried out by quantifying colony-forming units (CFU), and variables such as pH (5, 7, and 9) and application time (10, 20, and 30 min) formed the configuration of the analysis. The optimal disinfection point was reached within 20 min of the process, regardless of the disinfection method. In 10 min time, whenever the combined application was used, it showed improvement in efficiency at all pHs, most notably in alkaline medium. The application of UV radiation through LED is a recent technology and, therefore, has aroused interest in research worldwide.
Resumo A articulação sistemática de recursos hídricos envolve a utilização de instrumentos técnicos e de gestão capazes de minimizar impactos ambientais com otimização do capital disponível. As estações de tratamento de esgoto (ETE) são constituídas buscando a maior eficiência na remoção de contaminantes, incluindo microbiológicos, potencializando a qualidade da água a ser lançada nos corpos receptores. Em sistemas em que o tratamento terciário está presente, métodos de desinfecção como cloração e radiação ultravioleta (UV) são comumente utilizados como polimento final do efluente, e o acompanhamento da sua efetividade na desinfecção é extremamente importante para evitar gastos desnecessários. Desse modo, esta pesquisa buscou analisar a eficiência em desinfecção de amostras de efluente de uma ETE do sistema de saneamento do município de Indaial (SC), utilizando os métodos de ozonização e o processo combin |
---|---|
ISSN: | 1413-4152 1809-4457 1809-4457 |
DOI: | 10.1590/s1413-415220240020 |