The effect of different exposure parameters on proximal caries detection using the Kodak 9000 3D CBCT system
ABSTRACT Objective: The objective of study was to evaluate the diagnostic quality of CBCT images for caries lesions detection using different exposure parameters. Methods: Sixty extracted human teeth were selected and scanned using Kodak 9000 3D CBCT system, with the following exposure parameters co...
Gespeichert in:
Veröffentlicht in: | RGO - Revista Gaúcha de Odontologia 2017-12, Vol.65 (4), p.315-320 |
---|---|
Hauptverfasser: | , , , , , |
Format: | Artikel |
Sprache: | eng ; por |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
Zusammenfassung: | ABSTRACT Objective: The objective of study was to evaluate the diagnostic quality of CBCT images for caries lesions detection using different exposure parameters. Methods: Sixty extracted human teeth were selected and scanned using Kodak 9000 3D CBCT system, with the following exposure parameters combinations: 74 kV, 10mA; 74 kV, 12mA; 74 kV, 8 mA; 70 kV, 10 mA; 70kV, 12 mA; 70 kV e 8 mA; 70 kV, 6.3 mA. Two observers evaluated the images for caries presence using CS 3D Imaging Software. Each observer scored the proximal surfaces of each tooth on a 5-point scale. The scores were compared to histological sections used as gold standard. Accuracy for caries lesion detection was assessed for each exposure parameter combination and evaluated by means of ROC curve analysis. Results: The mean values for the areas under the ROC curves for each exposure parameter combination varied from 0.35 to 0.60. There was no statistical significant difference among protocols 1, 2, 4, 6 and 7. However, protocols 3 and 5 differed from all protocols. Conclusion: Although the highest dose protocol was the most efficient for proximal caries detection, the lowest dose protocol should be chosen based on the ALADA principle.
RESUMO Objetivo: Avaliar a qualidade de diagnóstico de imagens de TCFC para detecção de lesões de cárie utilizando parâmetros de exposição diferentes. Métodos: Sessenta dentes humanos extraídos foram selecionados e digitalizados usando o sistema Kodak 9000 3D TCFC, com as seguintes combinações de parâmetros de exposição: 74 kV, 10 mA; 74 kV, 12 mA; 74 kV, 8 mA70 kV, 10 mA; 70 kV, 12 mA; 70 kV e 8 mA; 70 kV, 6,3 mA. Dois observadores avaliaram as imagens para a presença de cárie utilizando o CS 3D Imaging Software. Cada observador pontuou as superfícies proximais de cada dente em uma escala de 5 pontos. Os escores foram comparados com cortes histológicos, utilizados como padrão-ouro. A precisão para detecção de lesões de cárie foi analisada para cada combinação de parâmetros de exposição e avaliada por meio de análise da curva ROC. Resultados: Os valores médios para as áreas sob as curvas ROC para cada combinação de parâmetro de exposição variou de 0,35-0,60. Não houve diferença estatística significativa entre os protocolos 1, 2, 4, 6 e 7. No entanto, os protocolos 3 e 5 diferem de todos os protocolos. Conclusão: Embora o protocolo de dose mais elevada foi o mais eficiente para a detecção da cárie proximal, o protocolo de dose mais baixa deverá ser escolhido com bas |
---|---|
ISSN: | 0103-6971 1981-8637 1981-8637 |
DOI: | 10.1590/1981-863720170002000053256 |