Spatiotemporal Structure of Hα Emission from the Detached Plasma in GAMMA 10/PDX
High-speed camera measurement was performed for analyses of detached plasma fluctuation in the GAMMA 10/PDX tandem mirror device. Significant spectral peaks at frequencies of 1.5 and 3 kHz were observed to have several local maxima along the vertical, near the entrance of the V-shaped target. Wavele...
Gespeichert in:
Veröffentlicht in: | Plasma and Fusion Research 2019/02/12, Vol.14, pp.2402036-2402036 |
---|---|
Hauptverfasser: | , , , , , , , , , , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
Zusammenfassung: | High-speed camera measurement was performed for analyses of detached plasma fluctuation in the GAMMA 10/PDX tandem mirror device. Significant spectral peaks at frequencies of 1.5 and 3 kHz were observed to have several local maxima along the vertical, near the entrance of the V-shaped target. Wavelet analysis indicated that 1.5- and 3-kHz fluctuations became non-simultaneously strong. Their phase relationships demonstrated inversion-symmetric and symmetric features with respect to the midplane. Such spectral patterns were interpreted as the line-integral of odd- and even-mode structures. It is suspected that the vertical edge part was due to radially elongated structures with an azimuthal phase shift. |
---|---|